Reasons why the wall switch socket cannot be powered on normally

Reasons why the wall switch socket cannot be powered on normally

  • Categories:Industry news
  • Author:
  • Origin:
  • Time of issue:2022-04-07 18:06
  • Views:

(Summary description)The failure of the wall switch socket to be normally energized is caused by the following reasons: 1. The switch and socket agent checks whether the zero line connector is short circuited. First disassemble the socket panel to see whether there is a problem at the connection. A zero line can be led from the normal working socket to the socket. If it can be powered on normally, it means that the original zero line is burnt out. Remove the original line and find a professional electrician for wiring again. 2. When the electric pen is tested, if the light is on, it means that the live wire is energized. It proves that the zero wire is disconnected, which will lead to no power in the socket. 3. Check whether the elasticity of the positive and negative contact pieces is good. When inserting the plug, check whether the contact between the elastic pieces in the socket and the plug is abnormal. 4. If the live line is energized, it cannot be energized normally. At this time, it is also necessary to check whether the zero line is open circuit (lack of zero).

Reasons why the wall switch socket cannot be powered on normally

(Summary description)The failure of the wall switch socket to be normally energized is caused by the following reasons:
1. The switch and socket agent checks whether the zero line connector is short circuited. First disassemble the socket panel to see whether there is a problem at the connection. A zero line can be led from the normal working socket to the socket. If it can be powered on normally, it means that the original zero line is burnt out. Remove the original line and find a professional electrician for wiring again.
2. When the electric pen is tested, if the light is on, it means that the live wire is energized. It proves that the zero wire is disconnected, which will lead to no power in the socket.
3. Check whether the elasticity of the positive and negative contact pieces is good. When inserting the plug, check whether the contact between the elastic pieces in the socket and the plug is abnormal.
4. If the live line is energized, it cannot be energized normally. At this time, it is also necessary to check whether the zero line is open circuit (lack of zero).

  • Categories:Industry news
  • Author:
  • Origin:
  • Time of issue:2022-04-07 18:06
  • Views:
Information

The failure of the wall switch socket to be normally energized is caused by the following reasons:
1. The switch and socket agent checks whether the zero line connector is short circuited. First disassemble the socket panel to see whether there is a problem at the connection. A zero line can be led from the normal working socket to the socket. If it can be powered on normally, it means that the original zero line is burnt out. Remove the original line and find a professional electrician for wiring again.
2. When the electric pen is tested, if the light is on, it means that the live wire is energized. It proves that the zero wire is disconnected, which will lead to no power in the socket.
3. Check whether the elasticity of the positive and negative contact pieces is good. When inserting the plug, check whether the contact between the elastic pieces in the socket and the plug is abnormal.
4. If the live line is energized, it cannot be energized normally. At this time, it is also necessary to check whether the zero line is open circuit (lack of zero).

Keyword:

Related to recommend

With so many specifications and types of plugs and want to clearly understand what kind of power plugs the customer needs, it is necessary to communicate with the customer, and change the sample of the plug to the customer when necessary, and let them confirm.
See more information 白箭头 黑箭头
Arrange the positions of switches and sockets reasonably from a practical point of view. For example, exhaust fan switches and toilet telephone sockets should be installed near the toilet, not on the wall where the toilet enters. In order to prevent the connection from being pulled out of the plug or socket by accidental pulling, the national standard stipulates that the connection point of the rewirable plug and the socket must be a screw terminal, and there must be a flexible cord fixing part to strengthen the tensile force, only to be integrated Only non-rewirable plugs or sockets are allowed to be soldered.
See more information 白箭头 黑箭头
Arrange the positions of switches and sockets reasonably from a practical point of view. For example, exhaust fan switches and toilet telephone sockets should be installed near the toilet, not on the wall where the toilet enters.