(Summary description)Design and analysis of main parts of switch socket Design of main parts of switch socket: the fixing mode of vacuum interrupter is a key factor affecting the service life of Engineering switch socket. No matter which fixing mode is adopted, attention should be paid to minimize the possible force on the vacuum interrupter to avoid mechanical damage to the vacuum interrupter. The vacuum interrupter is fixed in the following three ways: the static end is fixed, and the vacuum interrupter is fixed by the static conductive rod of the vacuum interrupter; The moving end is fixed, and the vacuum arc extinguishing chamber is fixed by the flange plate at the moving end of the vacuum arc extinguishing chamber. Generally, the vacuum arc extinguishing chamber is erected; Both ends are fixed, and the two ends of the driven and static flange of the vacuum interrupter are pressed and fixed with the insulating parts of the engineering switch socket and the upper and lower clamping plates through the buffer rubber pad.

Design and analysis of main parts of switch socket

(Summary description)Design and analysis of main parts of switch socket
Design of main parts of switch socket: the fixing mode of vacuum interrupter is a key factor affecting the service life of Engineering switch socket. No matter which fixing mode is adopted, attention should be paid to minimize the possible force on the vacuum interrupter to avoid mechanical damage to the vacuum interrupter.
The vacuum interrupter is fixed in the following three ways: the static end is fixed, and the vacuum interrupter is fixed by the static conductive rod of the vacuum interrupter; The moving end is fixed, and the vacuum arc extinguishing chamber is fixed by the flange plate at the moving end of the vacuum arc extinguishing chamber. Generally, the vacuum arc extinguishing chamber is erected; Both ends are fixed, and the two ends of the driven and static flange of the vacuum interrupter are pressed and fixed with the insulating parts of the engineering switch socket and the upper and lower clamping plates through the buffer rubber pad.

  • Categories:NEWS CENTER
  • Author:
  • Origin:
  • Time of issue:2022-04-07 17:28
  • Views:
Information

Design and analysis of main parts of switch socket
Design of main parts of switch socket: the fixing mode of vacuum interrupter is a key factor affecting the service life of Engineering switch socket. No matter which fixing mode is adopted, attention should be paid to minimize the possible force on the vacuum interrupter to avoid mechanical damage to the vacuum interrupter.
The vacuum interrupter is fixed in the following three ways: the static end is fixed, and the vacuum interrupter is fixed by the static conductive rod of the vacuum interrupter; The moving end is fixed, and the vacuum arc extinguishing chamber is fixed by the flange plate at the moving end of the vacuum arc extinguishing chamber. Generally, the vacuum arc extinguishing chamber is erected; Both ends are fixed, and the two ends of the driven and static flange of the vacuum interrupter are pressed and fixed with the insulating parts of the engineering switch socket and the upper and lower clamping plates through the buffer rubber pad.

Keyword:

Related to recommend

With so many specifications and types of plugs and want to clearly understand what kind of power plugs the customer needs, it is necessary to communicate with the customer, and change the sample of the plug to the customer when necessary, and let them confirm.
See more information 白箭头 黑箭头
Arrange the positions of switches and sockets reasonably from a practical point of view. For example, exhaust fan switches and toilet telephone sockets should be installed near the toilet, not on the wall where the toilet enters. In order to prevent the connection from being pulled out of the plug or socket by accidental pulling, the national standard stipulates that the connection point of the rewirable plug and the socket must be a screw terminal, and there must be a flexible cord fixing part to strengthen the tensile force, only to be integrated Only non-rewirable plugs or sockets are allowed to be soldered.
See more information 白箭头 黑箭头
Arrange the positions of switches and sockets reasonably from a practical point of view. For example, exhaust fan switches and toilet telephone sockets should be installed near the toilet, not on the wall where the toilet enters.